OpenText Intelligent Capture: How to restore batches using Copy module (IaCopy.exe)
Copy (IaCopy.exe) utility can be used to restore batches
copied by the module or exported through Intelligent Capture Administrator
Steps:
1. To launch the Copy module - Go to Windows Start-> OpenText Intelligent Capture -> Copy
2. Log into the Intelligent Capture server.
3. Select Copy Batch
4. Select the Source tab, click on Directory
In the File name field, browse or type the directory path and file name to restore.
Wildcard characters (* and ?) can be used in the filename.
5. Select the Destination tab.
Type in the information for the destination Intelligent Capture server: Server, User, and Password.
Click OK restore the batch to the destination server.
Related Articles
OpenText Intelligent Capture: In Classification, the following error occurs when processing a batch: “Exception of type 'Dispatcher.ModuleCore.Log.DiaException' was thrown”
Cause: Image size exceeding system limit. Resolution: Check file size, dpi, dimensions in pixels. The documented maximum stage file size is 200 mb, and the recommended size varies by module. Refer to the following sections in the Intelligent Capture ...
OpenText Intelligent Capture: How to copy batches to a directory using BatchCopy
BatchCopy.exe utility can be used to copy batches from the Intelligent Capture server to a directory. Steps: 1. Run BatchCopy.exe In the Windows search tool, type in “BatchCopy” or launch "BatchCopy.exe” located under the binnt folder: C:\Program ...
OpenText Intelligent Capture: “Connection refused by remote host. Make sure server is operational” error occurs when logging into the server
Issue: When logging into Scanplus, the following error occurs “Connection refused by remote host. Make sure server is operational” Cause: The Intelligent Capture Service is not running, or the server cannot be reached. Resolution: 1. Verify that the ...
OpenText Intelligent Capture: IaCopy failing to copy and returning error code 6016 or 4585
Issue: IaCopy failing to copy a batch from the server to a directory. Cause: IaCopy settings need to be corrected/updated. Resolution: Error Code 6016: Could not log in; check username, password, and domain Error Code 4585: This operation requires a ...
OpenText Intelligent Capture: How to Publish IEE RecognitionModelData using DeploymentUtility.exe
DeploymentUtility.exe can be used to publish Information Extraction, IEE, learnt data to the same or different capture server. Steps: Download the RecognitionModelData configurations to a new capture solution folder on the client machine: ...